The_batching_controller
Gallery_SWEDA_The_batching_controller_1
Gallery_SWEDA_The_batching_controller_2
The_batching_controller
Gallery_SWEDA_The_batching_controller_1
Gallery_SWEDA_The_batching_controller_2
Full Screen

Weight processor PW-310 for multi-component batching control

  • The operator sets the dose values ​​for 2 components during two-speed loading or 4 components during single-speed loading;
  • Calculation and indication of the current weight of the component;
  • Accounting for the mass of each component, their sum, the number of batching cycles;
  • Maintaining the total and final masses of each component.

 

Inquire a price

Category:

Description

The weight processor PW-310 for controlling multi-component batching is used for automatic control of process equipment that carries out sequential loading of portions of components with their subsequent unloading.

 

The weight processor PW-310 converts the output voltage of the weighing device strain gauges into digital form, processes it logically and mathematically, and generates the corresponding signals into an external control circuit to ensure portioned weigh batching.

 

PW-310 allows the operator to set the dose values ​​of 2 components for two-speed loading or 4 components for single-speed loading.

 

During the batching process, the current weight of the next component is calculated and its value is displayed on the digital indicator.

 

Find out more about the equipment – subscribe to our TikTok

Technical data

Power supply
of an alternating-current mains with voltage 220 V, frequency 50±1 Hz
Overall dimensions, mm 254 х 182 х 90 (without cable glands)
Mass, kg, no more
2,5
Range of an input analogue signal of direct voltage, мV 0…10
Input discrete signal up to 8 channels of galvanically isolated DC signals with voltage of 12…24 V
Output discrete signal up to 8 channels of galvanically isolated DC signals with a voltage of 24 V and a load capacity of 0.5 A. The total load is no more than 40 VA.
Load cells power supply DC voltage 5V
Number of connected load cells (Rin=350 Ohm) up to 8
Load cell cable lengt 50 m maximum
Serial interface RS-485 / RS-232 and RS-485
Internal resolution, discharges 24
Industrial resolution, counts 40000
Commercial resolution, counts 10000
Division value
1; 2; 5х1; 0,1; 0,01; 0,001
Operating mode continuous
Service life, years, not less than 10
Temperature rangе,  °С from –10 to +50